Platinum-Ceramic-wire wound Temperature-Sensoren

Platinum-ceramic temperature sensors use as a housing base a ceramic tube in which there are two or four wire windings. Overall, platinum-ceramic temperature sensors are characterized by the widest temperature measuring range of all platinum temperature sensors. However, they are preferably used for measurements of higher temperatures or in the field of analysis and laboratory technology. Temperature sensors of the CR version are designed for operating temperatures of -200 ... +600°C and temperature sensors of the CRU design for operating temperatures of -200 ... +800°C.


Download Overview-platinum-resistance-temperature-detectors

CR Series -200°C ... +600°C


Wires


Palladium-Gold-Alloy

Sizes (DxL)

1,0 x 15mm

1,5 x 8mm

1,5 x 15mm

1,5 x 25mm

2,6 x 30mm

3,6 x 30mm

4,5 x 30mm

Nominal resistance


Pt100

2xPt100


Tolerance Classes


W 0.1 (Class 1/3B)

W 0.15(Class A)

W 0.3 (Class B)




CRU Series -200°C ... +800°C


Wires


Platinum

Sizes (DxL)


0,9 x 15mm

1,5 x 15mm

1,5 x 25mm

2,0 x 6mm

2,6 x 30mm

4,5 x 30mm

Nominal resistance


Pt100

2xPt100


Tolerance Classes


W 0.1 (Class 1/3B)

W 0.15(Class A)

W 0.3 (Class B)





α Therm


Alpha Therm GmbH - Your specialist for temperature-limiting

safety components, sensor elements or sensors

© 2018 Alpha Therm GmbH

v 2.4

Phone: +49 6202 / 575688 - 0

Home Products Contact About us Shop Imprint Data Protection

Temperature protection

Temperature Protection

Overload protection

Overload protection

Surge protection


Surge protection

Temperature sensor elements

Temperature Sensors

Temperature controller

Temperature controller

Online shop

Download product overview

Mechanical switches

Mechanical switches